Show a warning if the ASIO driver sample rate is not the rate that was requested.Added an option in the All SPL graph Align SPL dialog to use the average dB SPL of the selected measurements as the target.Level meters panel is resizeable in width and height.
Text exports of multi-input capture measurements can optionally include each input as well as the average.Multi-input RTA measurements are saved in the same multi-input average format as sweep measurements, showing the span of the individual inputs as an underlay.In multi-input capture mode the level meters can show the first 16 inputs being captured.In multi-input capture mode the RTA can show the first 16 inputs being captured in addition to their rms average.Added a button in the SPL & Phase graph controls to adjust the SPL alignment and weighting of multi-input capture measurements.Added a button on the RTA input selection dialog to configure the SPL alignment and weighting of multi-input captures.Added a button on the Measure dialog to configure the SPL alignment and weighting of multi-input capture measurements.macOS: Fixed colours in dark mode for the file chooser and some other components.Bug fix: Trying to average RTA measurements would produce an out of memory error.Bug fix: Decay graph would generate an exception if the slice interval was more than the window length in CSD mode.
#Rew install4j wizard series#
Limit the series R for capacitor component model fits to 1 ohm maximum for caps below 100 nF.Adjusted threshold for using more compact layouts so it is used for display height (or scaled height) of 720 pixels or less.The delay figure for the acoustic timing reference always uses the estimated IR delay/estimated IR start. Added an Analysis preference to choose whether the System delay figure for loopback measurements is based on the relative timing of the measured and loopback IR peaks (the default) or either the estimated IR delay relative to the loopback when the peak is close to the IR start or the estimated IR start time relative to the loopback when the peak is later (limited bandwidth devices).Added Burst Decay modes to the waterfall and spectrogram.Bug fix: TS params calculated QMS figure was too high and RMS figure was too low.Bug fix: Long comments could push buttons out of view on room sim image capture dialog.
#Rew install4j wizard how to#
Widened tolerance for channel gain mismatch on impedance open circuit calibration to 2 dB and added help text on how to balance channel gains.Added the current sample rate in the RTA window title.Added a dB Average button in the All SPL graph controls that averages the dB values of the selected traces.